3.8.6
,Adjustment
of oriented spindle stop function
Adjustment procedure
((
)
for encoder type oriented spin-
dle stop function)
(1)
Spindle stop position
Since there is no control means (potentiometer or ro-
tary switch) for stop position adjustment, stop posi-
tion should be adjusted by changing parameter setting
as described below.
(a)
With READY signal turned on, set
"3"
for parameter
"00"
and press SET switch.
0
(b)
After the spindle rotates
two revolutions and stops,
"27"
will be displayed by
the 7-segment LED readout.
Press
@
or
@
switch to adjust stop position.
The spindle remains rotating while switch is held
down.
The spindle rotates about 1 deg. for each
100 of data value (one revolution for 4096 of data
value).
(c)
After the stop position has been determined, remove
dial gauge or other measuring device
and press
m
switch.
After the completion of stop position adjustment,
turn off and on the power or press RESET switch to
reset.
(d)
When FR-SFJ is connected to M300 series CNC through
bus line,
the values set for parameters
"27"
and
"30"
should be also set for parameters
IPST]
and
0RS2 appearing on the NC display screen ("Spindle
parameter", page 2).
-
39
-