(7) To remove the sens-
or gear,
screw eye
bolts
(M8)
into the
tapped holes and ap
ply a tool shown to
the right to the
bolts.
After the removal
of the sensor gear,
rem_ove
the two eye
bolts.
(8) To install the sensor
gear again,
it must be shrinkage-fit at temperature with-
in
100°C
-
15OOC.
Note that excessively high temperature may cause distor-
tion to the gear.
cl
4 Bearings
(1)
(2)
Remove the shaft
case cover mount-
ing screws and the
bracket mounting
hexagon socket head
bolts and remove
the bracket on the
counter-load side.
Apply sealant.
/l
Bracket mounting bolt
I
When the bracket
on the counter-load
side is installed
again,
apply seal-
ing compound to
the fitting sur-
faces.
-
69
-