8 Program Example
8.3 FX3G/FX3U/FX3UC PLC program example
57
FX3U-64CCL User's Manual
1
Introduction
2
Specification
and function
3
System
Configuration
4
Installation
5
Wiring, Start-up
procedure
6
FX
3U
-64CCL
setting (switch
setting)
7
Buffer Memory
8
Program
Example
9
Troubleshooting
A
Version
Information
From previous page
M323~M100 BFM#77~#64
(RXDF~RX00)
M607
M8000
K1K0 K62
FNC 78
TO
K1
M8000
K1K0 K62
FNC 78
TO
K0
*Write remote input RX and remote register RWr
X027
K1K0 K60
FNC 78
TO
K1
M8000
M7
Unit ready, Link execution
Unit ready, Link execution
M55
K1K0 K60
FNC 78
TO
K0
K14K0 K64
FNC 78
TO
K4M100
M8000
END
M400
RWw consistency
accessibility start
RWw consistency
accessibility completed
Utilization of the read
result
This section determines
the value of the remote registers
to set depending on the
ON/OFF write condition of the
remote inputs
RX consistency
accessibility start
RX consistency
accessibility completed
User sequence processing
User sequence processing
X000
K1K0 K63
FNC 78
TO
K1
M8000
M7
Unit ready, Link execution
M55
K1K0 K63
FNC 78
TO
K0
K32K0 K304
FNC 78
TO
D10
M8000
RWr consistency
accessibility start
RWr consistency
accessibility completed
D41~D10 BFM#335~#304
(RWr1F~RWr00)
M7M55
BFM#207~#176(RWw1F~RWw00)
D81~D50
K32K0 K176
FNC 79
FROM
D50