3-14 Connection of the air tube
(1) Remove the stepping motor cover.
(2) Attach the air pressure regulator assembly (NO.) underneath the table with the wood
screws (NO.). These are enclosed in the accessory box.
(3) The prepared holes are provided for the wood screws on the rear surface of the table.
(4) Cut the part of size ø8 air tube (NO.) enclosed in the accessory box into about 1.5 meter
length then, insert one end of this air tube into the air fitting (NO.) of the manifold (NO.).
The manifold is jointed with the magnet valves (NO.) and located at the left side surface of
the sewing machine head.
(5) Beside, pass the other end of the air tube (NO.) through the cut out hole of the table top
then, insert it into the air outlet fitting (NO.) of the air pressure regulator (NO.) then, join
the other end of the resting tube with the suitable air coupling to be adopted with the air
supply source provided in your factory.
(6) One of the air couplings is enclosed in the accessory box
.