EasyManua.ls Logo

Mitsubishi TEJ50AE - Language Setting Mode

Mitsubishi TEJ50AE
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
27
-
1
5
2
6
3
7
9
4
8
10
4 Initial setting
If you press “F4 (Select)” switch on each MAIN menu screen on
previous page, the display changes to the following screens.
F4
F4
Operation pattern selection mode (TEJ50AE only)
Mode to select the operation mode
start/stop or continuous operation
(Page 39)
Printer output setting mode
The temperature graph is printed in this mode.
Provide a printer to print the graph.
(Option)
Alarm display mode
Up to 5 error codes and dates/times of alarm
occurred are displayed. These are cleared by
pressing “F3 (Clear) switch.
(Page 60)
Maintenance information display mode
Operation time and number of operations of
each device are displayed in this mode.
(Page 33)
Language setting mode
Selects a language (English, French, Italian,
Swedish or German). Press “F2 ()” or “F3 ()”
switch to select a language, and nalize the
selection by pressing “F4 (Set)” switch.
Sub-menu selection mode
Functions of the controller operability, or other,
are displayed and set in this mode.
(Page 28)
Operation information display mode
State of operation is displayed in this mode.
Option sensor temperature display mode
When the optional sensor is installed, the sensor
temperature is displayed in this mode. Unless
the option sensor is installed, it displays “Lo”.
Defrost interval timer setting mode
The defrost interval is displayed and set in this
mode. It is set at “6.0Hr” at the shipping from
factory. (Page 35)
Clear NextBack
Alarm
E010
E016
E013
16 Jan 2021 07:10
15 Jan 2021 08:15
30 Nov 2020 10:30
NextBack
Printer output
Printout period
Temp range
Center temp
12Hr
±
30℃
0℃
NextBack
Maintenance information
Unit operation time/2120Hr
SelectBack
Sub-menu
Controller sound setting
Calendar and clock setting
Set On Timer
.
7
20
°
C
-
Back
Option sensor disply
SetBack
Current setting
6.0Hr
SetBack
Language setting
German
English
French
F2 F3 F4F1
Unlock Lock NextBack
Operating information1 C000
HP
LP
AT
----
150kPa
----
TD
REV
125℃
90rps
Start-Stop Continuous SetBack
Current setting
Start-Stop operation
F4
F1
[Back] [Next]
Operating information2
State
EVT
Cooling
-24℃
Operating information2
State
EVT
A Cooling B Heating
-24℃ 16℃
* In case of TEJ50AEM

Table of Contents