44
-
1
5
2
6
3
7
9
4
8
10
5 Operation
RUN/STOP
F2
PRESET
MENU
DEFROST
F3 F4F1
Setting the preset temperature
1
Start the refrigeration unit. (☞ Page 41)
⇒
The display changes to the preset
setting screen. Right gure shows
the setting values at the shipping
from factory.
⇒
In the “Preset (Zone selection)”
mode (Right gure), press “F2
(Zone A)” or “F3 (Zone B)” switch
to select the compartment of which the setting temperature is changed.
⇒ The display changes to the mode screen of Step 3 below. Further proce
dure is same as in the case of 1-compartment model.
[In case of 1-compartment model]
Press the “Preset” switch.
F2 F3 F4F1
⇒
Desired preset temperature is set,
and the display returns to the
normal display screen.
Press “F1 (~ F4)” switch.
F2 F3 F4F1
⇒
The preset temperature is regis-
tered, and the display returns to the
normal display screen.
[Preset registration of current
setting temperature]
Hold down “F1 (~ F4)” switch for
3 seconds.
F2 F3 F4F1
[In case of 2-compartment model]
Press the “Preset” switch.
F2 F3 F4F1
-
5.0℃ 5.0℃ 20.0℃
-
18.0℃
Current setting
-
30.0℃
-
5.0℃ 5.0℃ 20.0℃
-
18.0℃
Current setting
-
18.0℃
-
5.0℃ 5.0℃ 20.0℃
-
30.0℃
Current setting
-
30.0℃
Zone A
Zone BBack
Preset(Zone selection)
1
2・3
4
Set
.
7
20
▲
°
C
-
▼ S-S⇔Cont
Set
Cooling
0
- .
°
C
30
Register