9 For emergency
Countermeasures
Refer to "List of alarm codes" for the contents of each alarm code and its
countermeasure. (
Refer to pages 62 and 63)
Surely follow the instructions of this operation manual
for the countermeasures of the troubles.
Otherwise, it may cause injury or an electric shock due to
unexpected start.
When you contact your nearest dealer
When you contact your nearest dealer for the trouble occurred during
operation of the refrigeration unit, give them the following information.
Company name
Kind of cargo
Customer’s name
Setting temperature
Company telephone number
Present inside container
temperature
Number of the plate
Type of the refrigeration unit
Specific condition of trouble
Present location of the vehicle
Alarm code displayed in the
LCD display area.
Destination
Resuming operation after an emergency stop
Resuming operation after an emergency stop
Press the [RUN/STOP] switch on the cabin controller to stop the unit.
(Confirm that the LCD display is turned off.)
Press the [RUN/STOP] switch once more to resume the operation of the
unit.
If the unit stops by the same trouble immediately after
the operation is resumed, stop the operation and
contact your nearest dealer.
Otherwise, it may cause serious damages or accidents.