Diagnostics
79
04/99 AWB 2700-1311 GB
Diagnostic byte for Suconet K stations
The diagnostic bytes for each station and any local
expansion modules connected to them can be
scanned to obtain more detail about the information
contained in the diagnostic status word. Only read
access is possible.
Every station and local expansion module on the
Suconet K line has its own status information. The
available information will depend on the type of
Suconet station or local expansion module that is
connected, i.e. the status information differs
according to the type of station.
The status information indicates, for example,
whether
The device ID is incorrect
A device has been disconnected from the
Suconet bus or is not responding
A short-circuit has occurred at a station’s digital
output, etc.
Code Meaning Description of the error
EIL Error Illegal Code An attempt was made to execute an illegal
controller operation.
EOS Error Operating
System
An error was detected in the operating
system. The PLC will have to be restarted.
ECA Error CRC
Application
The application has become corrupted.
EAH Error Application
Halt
The application stopped of its own accord.
There is a group message containing status
information for every station on the Suconet K
line. This information relates to the basic unit and
any local expansion modules (LE) connected to
it.