Input Modules
121
05/01 AWB2700-1384GB
10
Base element
Measurement data VDE 0611
Part 1/8.92/IEC 947-7-1/ 1989
Rated voltage/current/cross section 250 V/17,5 A/1,5 mm
2
Rated surge voltage/contamination class 4 kV/3
Connection technology in TOP construction tension clamp
Connection technology 2-, 3-wire
Wire strip length 8 mm
Crimpable wire
-max. range
-“e“ single core H 07V-U
-“f“ thin core H 07V-K
-“f“ with ferrules acc. to DIN 46228/1 (ferrules
crimped gas-tight)
0,13 to 2,5 mm
2
0,5 to 2,5 mm
2
0,5 to 1,5 mm
2
0,5 to1,5 mm
2
Plug gauge acc. to IEC 947 - 1/1988 A2
Continuous current on the ZVL distribution rail 17,5 A
General information
Width/Length/Height (mm) with TS 35 x 7,5
Base element/elec. module 2-wire 142/94/90
Base element/elec. module 3-wire 142/102/90
Weight 350 g, 370 g
g15 %