34-00-00
-GENERAL
CAUTION
Release
air
pressure
slowly
by
unrolling
rubber
All
flight
instruments
are
grouped
on
the
shock
tubing.
A
sudden
release
of
the
air
pressure
may
mounted
panel
directly
in
front
of
the
pilot.
Flight
in-
damage
airspeed
indicator.
struments
are
operated
by:
(1)
filtered
air
drawn
into
an
evacuated
instrument
case,
(2)
barometric
pressure
or
2
Pitot
system
hose
inspections.-8fter
pitot
system
barometric
impact
air
pressure
differences,
(3)
varia-
is
checked
for
leaks,
inspect
hose
sections
for
signs
of
tions
in
electric
current
due
to
mechanically
varied
deterioration.
Check
ail
tubing
for
brittleness,
checks
or
resistance,
(4)
reference
to
the
earths
magnetic
field
or
cracks
particularly
at
bends
or
connecting
points.
(5)
aircraft
electrical
power.
When
new
hose
is
installed,
recheck
system
for
leaks
The
glareshield
must
be
removed
and
plumbing
dis-
using
PITOT
SYSTEM
LEAK
TEST
procedure.
connected
on
many
flight
instruments
before
they
can
3.
Static
system
cleaning.-Blow
low
air
pressure
(10-
be
removed.
Remove
glareshield
attaching
screws,
25
PSI)
through
lines
from
disconnected
line
at
center
post
cover
screws.
Carefully
lift
center
post
airspeed
indicator
to
static
ports.
Cover
each
static
cover
anal
glareshield
from
panel.
Disconnect
port
separately
when
blowing
to
insure
that
each
line
is
glareshield
and
compass
lights,
clear.
Instrument
error
or
possible
damage
may
result
Reinstall
glareshield
in
reverse
sequence.
if
even
one
port
is
clogged
with
dirt
or
foreign
matter.
34-10-00
PITOT
STATIC
AIR
PRESSURE
CAUTION
SYSTEM
NEVER
BLOW
AIR
through
the
line
TOWARD
the
INSTRUMENT
panel;
to
do
so
will
seriously
Static
pressure
instruments
are
extremely
sensitive
to
damage
instruments.
When
blowing
back
through
pressure
changes,
therefore,
the
pitot
and
static
sys-
line
from
instrument
panel,
make
sure
that
no
air
tem
must
be
kept
free
from
moisture
and
obstructions.
is
blown
into
instruments.
Drain
pitot
and
static
systems
after
humid
or
wet
weather.
If
instrument
operation
is
erratic
or
inoperative
4.
Static
system
leak
tes´•t.-The
static
system
should
after
draining,
perform
the
following:
be
checked
for
leaks
in
accordance
with
instructions
in
1.
Pitot
system
leak
test.-(Make
sure
Master
Switch
Federal
Aviation
Regulation
91.171.
is
OFF
and
Gear
Control
is
in
DOWN
position.)
CAUTION
A.
Slip
end
of
a
short
rubber
hose
over
pitot
tube.
To
avoid
damaging
either
the
airspeed
indicator
or
B.
Close
open
end
of
hose;
slowly
roll
up
hose
the
landing
gear
airspeed
safety
switch
an
equal
until
airspeed
indicator
reads
150
MPH.
pressure
should
be
applied
to
the
pitot
side
of
the
C.
Clamp
hose
and
hold
for
one
minute.
indicator
while
leak
testing
the
static
system.
D.
If
airspeed
indicator
falls
more
than
9
KIAS,
within
one
minute,
check
system
for
leaks
and
tighten
5.
Alternate
static
source.-An
alternate
static
source
line
fittings.
valve
is
provided
to
change
the
static
air
source
from
E.
Repeat
steps
B,
C,
and
D
until
obtaining
less
outside
the
aircraft
to
inside
the
cabin.
The
valve
is
lo-
than
a
9
KIAS
indicator
reading
drop.
cated
on
the
lower
panel
under
the
pilots
control
column.
Airspeed
indicator
and
altimeter
readings
will
be
slightly
affected
when
using
the
alternate
static
source.
3410-01
HEATED
PITOT
TROUBLE
SHOOTING
TROUBLE
PROBABLE
CAUSE
REMEDY
ube
does
not
heat
or
clear
itself
of
Switch
circuit
breaker
tripped.
Reset
circuit
breaker.
ice
with
switch
on.
Open
circuit.
Repair.
Excessive
voltage
drop
be-
Check
for
bad
connections
in
connec-
tween
battery
and
pitot
head.
tors
and
cables
leading
to
the
pitot
Read.
Heating
element
burned
out.
Replace
pitot
head.
a4-OQ-OQ