EasyManua.ls Logo

Morco GB24 User Manual

Morco GB24
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
12/2023
UIN 236461 A02
User & Installation Instructions
GB24 & GB30
IV
Propane
88
restart
Morco House, Riverview Road, Beverley, East Yorkshire, HU17 0LD
Morco Products Ltd
Tel: 01482 325456 Email: sales@morcoproducts.co.u
k
Website: www.morcoproducts.co.uk
To Domestic Hot Water:
GB24-Propane Minimum 8.0 kW
GB30-Propane Minimum 8.0 kW
GB24-Propane Maximum 24.2 kW
GB30-Propane Maximum 30.3 kW
To Central Heating:
GB24-Propane Minimum 8.0 kW
GB30-Propane Minimum 8.0 kW
GB24-Propane Maximum 24.2 kW
GB30-Propane Maximum 24.2 kW
BOILER OUTPUT
min
max
min
max
mode
off
e
restart
IV

Other manuals for Morco GB24

Questions and Answers:

Morco GB24 Specifications

General IconGeneral
Output24 kW
Dimensions700 x 400 x 250 mm
MountingWall Mounted
Central Heating Output (kW)24 kW
Domestic Hot Water Output (kW)24 kW
ERP RatingA
Warranty2 years
Fuel TypeNatural Gas
Flow Rate10 l/min

Summary

User Instructions and Boiler Operation

Safety and Regulatory Compliance

Covers gas safety, installation rules, and important safety notes.

Gas Leak Safety Procedure

Procedure to follow in case of a suspected gas leak.

Boiler Troubleshooting Guide

Flowchart for diagnosing common boiler issues.

General Installation Requirements

Installation Recommendations

Key recommendations and regulatory compliance for installation.

Flue Terminal Positioning Rules

Specifications for the correct and safe positioning of the flue terminal.

Gas Supply Requirements

Specifies requirements for a safe and correct gas supply connection.

Installation Procedures

Boiler Fitting and Mounting

Step-by-step guide for physically installing the boiler on the wall.

Water and Gas Connections

Guidance on making secure water and gas connections to the boiler.

Air and Flue System Installation

Information on approved flue systems and their installation.

Determining Maximum Flue Length

Guidelines for calculating the maximum permissible flue length.

Flue Length Calculation Details

Detailed methods for determining flue length for rear and side installations.

Installing the Flue System Through Wall

Steps for fitting the flue through the wall and attaching the turret.

Condensate Drain Pipe Requirements

Requirements and methods for condensate drain pipe installation.

Commissioning Instructions

General Commissioning Prerequisites

Prerequisites and general steps before starting the commissioning process.

Final Checks and User Handover

Final checks and handover procedures to the user.

Routine Servicing Instructions

Routine Servicing Schedule

Recommended intervals and procedures for routine boiler servicing.

Combustion Performance Check Requirements

Requirements and competence for checking combustion performance.

Fault Codes and Troubleshooting

Fault Finding Chart Main Menu

Main menu for diagnosing faults using error codes.

L1: Flow Temperature Overheat Lockout

Troubleshooting steps for overheat lockout faults (L1).

L2: Ignition Lockout

Troubleshooting steps for ignition lockout faults (L2).

L6: False Flame Lockout

Troubleshooting steps for false flame lockout faults (L6).

F1: Low Water Pressure

Troubleshooting steps for low water pressure faults (F1).

F2/Fn/Ln: Flame Loss

Troubleshooting steps for flame loss faults (F2, Fn, Ln).

F3: Fan Fault

Troubleshooting steps for fan faults (F3).

F4/L4: Flow Thermistor Fault

Troubleshooting steps for flow thermistor faults (F4, L4).

F5/L5: Return Thermistor Fault

Troubleshooting steps for return thermistor faults (F5, L5).

F6: Outside Sensor Fault

Troubleshooting steps for outside sensor faults (F6).

No Display Fault

Troubleshooting steps when the boiler display shows no information.

Combustion Check Procedures

Combustion Check Flowchart

Flowchart for checking CO level and combustion ratio on commissioning.

Related product manuals