104
PTT Sidetone Use the UP/DOWN arrow keys to enable/disable this option. If this 
feature is enabled, a sidetone will be generated during encoding of a 
Stat-Alert PTT-ID and STAR PTT-ID. Sidetones are not compatible with 
PTT-ID on de-key.
The default is Enabled.
Emergency Sidetone Use the UP/DOWN arrow keys to enable/disable this option. If this 
feature is enabled, a sidetone will be generated during encoding of a 
Stat-Alert Emergency ID.
The default is Disabled.
Remote Monitor This feature is limited to HT 1000 “B” models and VISAR models with 
firmware version 2.06 or later. If this field is enabled on a radio having an 
earlier version firmware or on a JT1000 radio, it will have no effect.
Use the UP/DOWN arrow keys to enable or disable this field. If this 
field is set to Enabled, the decoding for the MDC Remote Monitor 
command will be activated. The Remote Monitor command will cause 
the radio to key up and transmit ambient audio for a period of time 
that is controlled by the command itself. The time period will be 
determined by multiplying a value of 20 seconds with the number in 
the MDC Remote Monitor command’s multiplier field.
The default is Disabled.
Radio Check Use the UP/DOWN arrow keys to enable/disable this option. If this 
option is enabled, the dispatcher can send a message to a radio which 
stimulates a specific response, verifying that the radio is turned on and 
within range of the system.
The default is Enabled.
MDC Auto Reset Use the UP/DOWN arrow keys to enable/disable this timer. This 
option enables you to use the Auto-Reset timer for MDC Selective Call 
signalling.
The Auto-Reset timer allows a two-way conversation to follow a 
Selective Call. When the conversation ends, the radio will 
automatically be returned to Page mode. The auto reset timer specified 
on the RADIO SYSTEM CONFIGURATION screen (F4/F3/F2) will be 
initiated after the Selective Call is received and the Alert Tone 
sequence is sounded. The radio will return to Page mode (signalling 
squelch) if:
• There is a period of inactivity (no carrier) on the channel for the 
duration of the Auto Reset timer; and
• No PTT presses occur for the duration of the timer.
If carrier is detected, or PTT pressed, the timer will be reset and 
restarted. The timer is common to both Quik-Call and MDC signalling 
systems. Its duration is set on the RADIO SYSTEM CONFIGURATION 
screen (F4/F3/F2) screen.
The default is Enabled.