EasyManua.ls Logo

Motorola HT-1000 - Alert Tone Configuration

Motorola HT-1000
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
91
Alert Tone
Configuration
From the MAIN MENU, press F4, F3 and then F4 again to access this
screen.
From this screen, you can configure options for the radio’s alert tone
operation.
Function Key Descriptions
F5 - PRINT Prints the current system configuration.
F9 - DEFAULT Resets the fields on this screen to their default values.
Field Definitions
Master Alert Tone Control This field allows you to enable/disable all alert tones controlled from
this and all other screens, with two exceptions. These are tones which
cannot be disabled from the RSS: MDC Select Call Alert and Quik-Call
II Select Call Alert.
If the Master Alert Tone Control is set to Disabled, none of the Alert Tones
can be enabled individually until the Master Alert Tone Control is enabled.
If you want to disable all alert tones, only the Master Alert Tone
control needs be changed. All individual tones will then be
automatically disabled.
Note: There are two actions that will override and reset the state
of the Master Alert Tone Control feature. These are:
1. Use of the F9 default key on any screen that has alert fields.
2. Changing the setting for the Signalling Type field on the
MDC/STAR/ATIS OPTIONS screen (F4/F3/F7/F3) which sets the
new signal type defaults.
When the Master Alert Tone control is re-enabled, all individual
tones will still be disabled. Therefore, the desired tones must be
turned on individually.
The default is Enabled.
DCD
MOTOROLA Radio Service Software Use <: keys to enable/disable feature
HT/JT1000/VISAR Model : Use <Enter> to go to next feature.
Serial:
CHANGE:RADIO:ALERT TONE CONFIG
Alert Tone Configuration
------------------------
Master Alert Tone Control.....Enabled Mandown Pre Alert.............Enabled
Power Up Alert................Enabled Tx Low Battery Alert..........Enabled
Illegal Channel Alert.........Enabled Rx Low Battery Alert.........Disabled
Timeout Timer Alert...........Enabled
Timeout Timer Pre-Alert......Disabled Low Battery Alert Intvl (sec).....120
Alert Volume Tx...................176
PL Defeat Alert...............Enabled Alert Volume Rx...................176
Scan Programming Alert........Enabled
Priority Chan Lock Alert......Enabled
PTT Tx Inhibit Alert..........Enabled
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
HELP PRINT DEFAULT EXIT