EasyManua.ls Logo

Motorola HT-1000 - Permanent Monitor; Tx Inhibit on Busy (Smart PTT)

Motorola HT-1000
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
177
DOS Coast Time Time that Data Detect can be lost before
unmute
CHANGE:RADIO:SIG:MDC:OPT
Auto Timed Mute
Duration
Length of auto-mute on Carrier Detect CHANGE:RADIO:SIG:MDC:OPT
MDC OPTIONS DECODE CHANNEL
Auto Reset Timer Radio-wide setup of Auto Reset Timer length CHANGE:RADIO:SYS CONFIG
Stat-Alert/ATIS Sel Cal Enables Select Call for the current channel CHANGE:CHANNEL
PTT-ID Enables PTT-ID Encode for the current channel CHANGE:CHANNEL
MDC/STAR/ATIS
Decode
Enables Signalling Decode for the current
channel
CHANGE:CHANNEL
Talkaround Incompatible with PTT-ID and RAT if enabled CHANGE:CHANNEL
Repeater Access Enables Repeater Access for the current channel CHANGE:CHANNEL
Signalling Muting
Dispatch
Sets whether the radio responds to only
Selective Calls or to normal condition as well
CHANGE:CHANNEL:OPT
Accept Alert Enables chirp when RAT Side Button is pressed CHANGE:RADIO:SIG:MDC:RAT ID
Silent Pretime Sets Pretime between Keyup and first bit of RAT
data
CHANGE:RADIO:SIG:MDC:RAT ID
Code 1 - Code 8 Sets Repeater ID to be accessed CHANGE:RADIO:SIG:MDC:RAT ID
MDC Decode Scan Enables MDC Decoder in scan on MDC-
enabled channels
CHANGE:RADIO:SCAN:CONFIG
MDC Sel Call Scan Enables scanning for MDC Sel-Cal on MDC-
enabled channels
CHANGE:RADIO:SCAN:CONFIG
Remote Monitor Enables radio to respond to the MDC Remote
Monitor command
CHANGE:RADIO:SIG:MDC CONFIG
Sticky Revert Enables radio to operate in the Sticky Revert
Mode when MDC Emergency Revert is used
CHANGE:RADIO:SIG:MDC CONFIG
Sticky Revert Alert Enables radio to generate Alert Tone whenever
Operator keys up on the Sticky Revert Channel,
which may be different from the selected
channel
CHANGE:RADIO:SIG:MDC:CONFIG
Open Mic Duration Enables radio to automatically key up with
Open Microphone for a programmable amount
of time after MDC Emergency Alarm Sequence
is completed
CHANGE:RADIO:SIG:MDC:OPT
Mandown Pre-Alert
Delay
Length of time from the point that the
mandown switch is pressed until the time that
an alert is generated
CHANGE:RADIO:SIG:MDC:OPT
Mandown Post-Alert
Delay
Length of time between the mandown alert
tone and transmission of the Emergency Alarm
sequence
CHANGE:RADIO:SIG:MDC:OPT
MDC Signalling
Field Function Location

Table of Contents

Other manuals for Motorola HT-1000

Related product manuals