TEST SETUP & TESTING MTP700/MTP750 Portable Radios / Basic Service Manual 5-3
Test Check List
The following table summarises the required test setups.
Note: Values for 380-430 MHz radio in brackets [ ].
No. Test Name Test Setup Radio Setup Test Conditions Limits
1. Base Station
Registration
Control
Channel
861.0125MHz
[ 420.0125MHz ]
2440
[ 800 ]
Trafic Channel 2140 [ 800 ]
Time Slot 3
Country Code 753 [ 234 ]
Network Code 2361 [ 75 ]
Base Color 1
Location Area 22 [ 0000 ]
Min Rx Level -110dBm
Max Tx Level 30dBm
Access
Parameter
-53dBm
Mobile Power 30dBm
Burst Type Normal
2. Receiver RSSI RF Gen Level Test Page
Cells Info
RSSI
Trace
-50dBm
3. Transmitter
Tests
RF Gen Level Group Mode -90dBm
Burst Power 28-31.5dBm
Timing Error <=0.25 Symbols
Frequency
Error
-/+ 80Hz
Vector Error Max 10% RMS,
Max 30% Peak,
Max 5% Residual
4. Call Processing
Talk Back
RF Gen Level
1 kHz Test
Signal
Group Mode -90dBm
5. Call Processing
Call to Mobile
RF Gen Level
Private Call
Private Mode -90dBm
Burst Power 28-31.5dBm
Timing Error <=0.25 Symbols
Frequency
Error
-/+ 80Hz
Vector Error Max 10% RMS,
Max 30% Peak,
Max 5% Residual