EasyManua.ls Logo

Motorola Symbol DS9808 - RS-232 Parameter Defaults

Motorola Symbol DS9808
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-232 Interface 7 - 3
RS-232 Parameter Defaults
Table 7-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s)
provided in the RS-232 Host Parameters section beginning on page 7-4.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 7-1
RS-232 Host Default Table
Parameter Default
Page
Number
RS-232 Host Parameters
RS-232 Host Types Standard 7-6
Baud Rate 9600 7-7
Parity Type None 7-9
Data Bits 8-Bit 7-9
Check Receive Errors Enable 7-10
Hardware Handshaking None 7-10
Software Handshaking None 7-12
Host Serial Response Time-out 2 Sec 7-14
RTS Line State Low RTS 7-15
Beep on <BEL> Disable 7-15
Intercharacter Delay 0 msec 7-16
Nixdorf Beep/LED Options Normal Operation 7-17
Ignore Unknown Characters Send Bar Code 7-17
Note: The Symbol DS9808 supports one stop bit only.