5-34 Disassembly/Reassembly Procedures Ensuring Radio Immersibility
5.8.9.2 Battery Contact Seal
To replace the Battery Contact Seal:
1. Refer to Section 5.6 "Radio Disassembly – Detailed" on page 5-6 to remove the Battery
Contact Seal.
2. Remove the Battery Contact Seal from the Chassis.
3. Inspect the Battery Contact Seal, Chassis and surrounding areas for foreign material that
might prevent the Battery Contact Seal from sealing properly.
4. Install a new Battery Contact Seal; discard the old Seal.
5. Reassemble the chassis assembly followed by installing into Front Cover. (Refer to Section
5.7 "Radio Reassembly - Detailed" on page 5-21).
IMPORTANT: Both Air Ventilation Label (54012316001) and Gasket (3286058L01)
need to be replaced after vacuum test, pressure test or water leakage
troubleshooting.