NPort 5000 Series User Manual
132
IP Address Report
When the NPort is used in a dynamic IP environment, users must spend more time with IP management
tasks. NPort serial device servers help out by periodically reporting their IP address to the IP location
server, in case the dynamic IP has changed.
1. Configure the NPort with Dynamic IP settings (DHCP, BOOTP, or DHCP/BOOTP). Assign the remote Auto
IP report server’s IP address and UDP port.
2. Select the IP Address Report, and click the right mouse button to select Settings.
3. Configure the Local Listen Port to be the same as the NPort’s “Auto report to UDP port” setting.

Table of Contents

Other manuals for Moxa Technologies NPort 5110A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies NPort 5110A and is the answer not in the manual?

Moxa Technologies NPort 5110A Specifications

General IconGeneral
Isolation1.5 kV
CertificationCE, FCC
Serial interface typeRS-232
Serial ports quantity1
Ethernet LAN data rates10, 100 Mbit/s
Supported network protocolsICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, HTTP, SMTP, IGMP v1/2
Compatible operating systemsSCO Unix, OpenServer UnixWare v2.1, v7 Unix SVR 4.2 Unix QNX 4.25, QNX 6 Solaris 10 FreeBSD AIX 5.x HP-UX 11i Mac OS v10.3 Linux v2.4.x, v2.6.x
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)5 - 95 %
Input voltage12 - 48 V
SafetyUL, LVD
Weight and Dimensions IconWeight and Dimensions
Weight340 g
Dimensions (WxDxH)52 x 80 x 22 mm