mr
.
steam
®
C U S E R I E S Installation, Operating & Maintenance Manual
11
STEAM ROOM GUIDELINES
IMPORTANT: The following general information should be used in conjunction with your architect,
designer and contractor in determining all factors necessary in providing a suitable and safe steam
room environment for your bathers.
IMPORTANT: Owners/operators should obtain a copy and familiarize themselves with the latest edi-
tion of the American College of Sports Medicine Health/Fitness Faculty Standards and Guidelines
(ISBN: 0736051538), or a similar resource and reference publication, and refer to those guidelines for
the proper and safe operation of a spa facility including steam rooms.
STEAMHEAD
(3/4” N.P.T.)
1. For steam rooms constructed of tile, marble or similar
non-porous heat-resistant materials for the enclosure,
locate steam head 12 inches above steam room floor
and install Mr.Steam PN CU-103985 acrylic shield on
each steamhead.
IMPORTANT: For Steam rooms using acrylic, fiberglass or
other non-heat resistant materials used for steam room
enclosure, install each steam head 20-30 inches above the
floor.
2. Locate each steamhead away from bather seating area
and away from traffic patterns as required to prevent
incidental contact with steamhead or direct steam emis-
sions.
3. Install each steamhead with steam slots facing to the left
and right as shown in the diagrams.
4. NOTE: To preserve the steamhead finish, do not use
wrench or other tools to tighten. Use of proper thread
sealant and hand tightening is usually sufficient.
5. Apply a bead of silicone around the steamhead where it
meets the wall as required to prevent moisture damage.
ACRYLIC SHIELD
Apply a small bead of silicone in the grooves on the top
and bottom of the steamhead. Place an Acrylic Shield (PN
103985) over the steamhead until the tabs engage the
grooves in the steamhead.
IMPORTANT: Do not use with fragrance containing
aldehydes. Acrylic Shield damage may result. Mr. Steam oils
are approved for use with this acrylic shield.
Fully Assembled
Assembly
Steam Head
Steam Pipe
Acrylic Sheild
Use Teflon or equal
sealant on pipe threads
Steam
Supply Pipe
Fill gap with silicone or
equal sealant as required
for moisture seal
Diagram A
Steam Head
3/4”
Finished interior face
of steam room wall
Diagram B