Operating Manual
ProtoNode Start-up Guide
Revision: 3.G
Document No.:T18610
Print Spec: 10000005389 (F)
MSAsafety.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the MSA fieldserver ProtoNode and is the answer not in the manual?

Summary

About the MSA Field Server ProtoNode

Certification

Details BTL and LonMark certifications, signifying product quality and interoperability standards adherence.

BACnet;LonWorks Setup through ProtoNode

Features

Overview of ProtoNode's capabilities, including Ethernet interface and multi-protocol support.

Installation Steps for the Customer

Step-by-step guide for customers to install and configure the ProtoNode, including DIP switch settings.

Record Identification Data

Instructions on recording the unique part number of the ProtoNode for technical support purposes.

Configure the DIP Switches

Guidance on setting the DIP switches for baud rate, Node-ID/Device Instance, and configuration files.

Interfacing ProtoNode to Host OEM Device

ProtoNode FPC-N34 and FPC-N35 Showing Connection Ports

Diagrams and labels identifying the connection ports for ProtoNode FPC-N34 and FPC-N35 models.

Device Connections to ProtoNode

Details on connecting RS-485 devices to the 6-pin Phoenix connector of the ProtoNode.

Resistor and Power Jumper Information

Explanation of bias resistors' function in keeping the RS-485 bus in a known state during idling.

Termination Resistor

Information on termination resistors used to reduce noise and keep RS-485 bus lines together.

Power Jumper Settings

Details on setting the power jumper (Position A/B) for different power supply requirements.

Wiring Field Port to RS-485 BMS Network

Instructions for connecting the RS-485 network wires to the ProtoNode FPC-N34 and configuring EOL termination.

Wiring Field Port to a LonWorks Network

Guidance on connecting the ProtoNode to a LonWorks network using approved cables.

Power up the ProtoNode

Connect the PC to the Gateway

Connecting to the Gateway via Ethernet

Steps for connecting a PC to the ProtoNode via an Ethernet cable for initial setup.

Changing the Subnet of the Connected PC

Guide for configuring the PC's IP address and subnet mask to match the ProtoNode's network.

Navigate to the Login Page

Instructions on how to access the FieldServer's web login page using a web browser.

Setup Web Server Security

Login to the FieldServer

First-time login procedure for the FieldServer GUI, including handling browser security warnings.

Select the Security Mode

Options for selecting the web server security profile: HTTPS with trusted certificates or HTTP.

Configure the FieldServer

Setting IP Address for Field Network

Guide for configuring IP settings, BACnet parameters, and network numbers within the FieldServer GUI.

Accessing the FieldServer Manager

Information on accessing the FieldServer Manager tab for cloud connectivity, configuration, and maintenance.

LonWorks (FPC-N35): Commissioning the ProtoNode on a LonWorks Network

Commissioning the ProtoNode FPC-N35 on a LonWorks Network

Steps for commissioning the ProtoNode FPC-N35 by a LonWorks administrator, including service pin activation.

Instructions to Download XIF File from ProtoNode FPC-N35 Using Browser

Procedure to download the XIF file from the ProtoNode FPC-N35 via a web browser for LonWorks configuration.

Troubleshooting

Lost or Incorrect IP Address

Steps to locate a lost or incorrect IP address using the FieldServer Toolbox utility.

Viewing Diagnostic Information

How to view connection status and diagnostic information through the web browser or FieldServer Toolbox.

Checking Wiring and Settings

Troubleshooting guide for COM issues on Modbus RTU/TCP and Field COM protocols by checking wiring and settings.

Taking a FieldServer Diagnostic Capture

Procedure for performing a diagnostic capture and emailing it to technical support for accelerated problem diagnosis.

LED Functions

Explanation of the LED indicators (SPL, RUN, ERR, RX, TX, PWR) on the ProtoNode for status monitoring.

Additional Information

Update Firmware

Instructions for updating the ProtoNode's firmware using the web browser and file transfer.

BACnet: Setting Network_Number for more than one ProtoNode on Subnet

Guide for assigning unique BACnet Network_Number values when multiple ProtoNodes are on the same subnet.

Reading Data Arrays

Steps to access and view data arrays, map descriptors, and offsets via the browser interface.

Change Web Server Security Settings After Initial Setup

Instructions on modifying web server security settings, requiring a FieldServer reboot for changes to take effect.

Change User Management Settings

Instructions for managing user accounts, including creating, editing, deleting, and password changes.

Routing Settings

Guide for setting up IP routing rules for internet and network connections, defining destination, netmask, and gateway.

Specifications

Technical specifications for ProtoNode FPC-N34/N38 and FPC-N35/N39 models, including connections and approvals.

Compliance with UL Regulations

Instructions and requirements for UL compliance, including power supply, cabling, and installation environment.

A Bank DIP Switch Settings

Detailed table of A Bank DIP switch settings for various addresses (A0-A7) to configure Node-ID/Device Instance.

Limited 2 Year Warranty

Summary

About the MSA Field Server ProtoNode

Certification

Details BTL and LonMark certifications, signifying product quality and interoperability standards adherence.

BACnet;LonWorks Setup through ProtoNode

Features

Overview of ProtoNode's capabilities, including Ethernet interface and multi-protocol support.

Installation Steps for the Customer

Step-by-step guide for customers to install and configure the ProtoNode, including DIP switch settings.

Record Identification Data

Instructions on recording the unique part number of the ProtoNode for technical support purposes.

Configure the DIP Switches

Guidance on setting the DIP switches for baud rate, Node-ID/Device Instance, and configuration files.

Interfacing ProtoNode to Host OEM Device

ProtoNode FPC-N34 and FPC-N35 Showing Connection Ports

Diagrams and labels identifying the connection ports for ProtoNode FPC-N34 and FPC-N35 models.

Device Connections to ProtoNode

Details on connecting RS-485 devices to the 6-pin Phoenix connector of the ProtoNode.

Resistor and Power Jumper Information

Explanation of bias resistors' function in keeping the RS-485 bus in a known state during idling.

Termination Resistor

Information on termination resistors used to reduce noise and keep RS-485 bus lines together.

Power Jumper Settings

Details on setting the power jumper (Position A/B) for different power supply requirements.

Wiring Field Port to RS-485 BMS Network

Instructions for connecting the RS-485 network wires to the ProtoNode FPC-N34 and configuring EOL termination.

Wiring Field Port to a LonWorks Network

Guidance on connecting the ProtoNode to a LonWorks network using approved cables.

Power up the ProtoNode

Connect the PC to the Gateway

Connecting to the Gateway via Ethernet

Steps for connecting a PC to the ProtoNode via an Ethernet cable for initial setup.

Changing the Subnet of the Connected PC

Guide for configuring the PC's IP address and subnet mask to match the ProtoNode's network.

Navigate to the Login Page

Instructions on how to access the FieldServer's web login page using a web browser.

Setup Web Server Security

Login to the FieldServer

First-time login procedure for the FieldServer GUI, including handling browser security warnings.

Select the Security Mode

Options for selecting the web server security profile: HTTPS with trusted certificates or HTTP.

Configure the FieldServer

Setting IP Address for Field Network

Guide for configuring IP settings, BACnet parameters, and network numbers within the FieldServer GUI.

Accessing the FieldServer Manager

Information on accessing the FieldServer Manager tab for cloud connectivity, configuration, and maintenance.

LonWorks (FPC-N35): Commissioning the ProtoNode on a LonWorks Network

Commissioning the ProtoNode FPC-N35 on a LonWorks Network

Steps for commissioning the ProtoNode FPC-N35 by a LonWorks administrator, including service pin activation.

Instructions to Download XIF File from ProtoNode FPC-N35 Using Browser

Procedure to download the XIF file from the ProtoNode FPC-N35 via a web browser for LonWorks configuration.

Troubleshooting

Lost or Incorrect IP Address

Steps to locate a lost or incorrect IP address using the FieldServer Toolbox utility.

Viewing Diagnostic Information

How to view connection status and diagnostic information through the web browser or FieldServer Toolbox.

Checking Wiring and Settings

Troubleshooting guide for COM issues on Modbus RTU/TCP and Field COM protocols by checking wiring and settings.

Taking a FieldServer Diagnostic Capture

Procedure for performing a diagnostic capture and emailing it to technical support for accelerated problem diagnosis.

LED Functions

Explanation of the LED indicators (SPL, RUN, ERR, RX, TX, PWR) on the ProtoNode for status monitoring.

Additional Information

Update Firmware

Instructions for updating the ProtoNode's firmware using the web browser and file transfer.

BACnet: Setting Network_Number for more than one ProtoNode on Subnet

Guide for assigning unique BACnet Network_Number values when multiple ProtoNodes are on the same subnet.

Reading Data Arrays

Steps to access and view data arrays, map descriptors, and offsets via the browser interface.

Change Web Server Security Settings After Initial Setup

Instructions on modifying web server security settings, requiring a FieldServer reboot for changes to take effect.

Change User Management Settings

Instructions for managing user accounts, including creating, editing, deleting, and password changes.

Routing Settings

Guide for setting up IP routing rules for internet and network connections, defining destination, netmask, and gateway.

Specifications

Technical specifications for ProtoNode FPC-N34/N38 and FPC-N35/N39 models, including connections and approvals.

Compliance with UL Regulations

Instructions and requirements for UL compliance, including power supply, cabling, and installation environment.

A Bank DIP Switch Settings

Detailed table of A Bank DIP switch settings for various addresses (A0-A7) to configure Node-ID/Device Instance.

Limited 2 Year Warranty

MSA fieldserver ProtoNode Specifications

General IconGeneral
BrandMSA
Modelfieldserver ProtoNode
CategoryGateway