4 Technical Data
4.1 Product data 12V4000C11, 12V4000C11R
Legend
DL Ref. value continuous power (CP): Continuous power under standard conditions
BL Ref. value fuel stop power (FSP): Maximum engine power; not available for continuous operation in
some applications (control reserve)
A Design value: Value required to design an external system (plant)
R Reference value: Typical average value for information, only partially suitable for design purposes
L Limit: Value which must not be violated (lower limit value, min. value / upper limit value, max. value),
not suitable for design purposes
N Non-defined value: Value yet to be or not defined
- Not applicable: Module does not apply to this product type
X Applicable: Module applies to this product type
> Actual value must be greater than the specified value.
< Actual value must be less than the specified value.
* Value not adequately verified (tolerance +/- 10%)
** Value not adequately verified (tolerance +/- 5%)
ID Product type Application Engine speed List perform-
ance
1 12V4000C11
(T1237K11-110
2)
Industrial / vehicle
main drive
5A continuous opera-
tion, unrestricted
5B continuous opera-
tion, variable
1900 rpm 1286 kW
1725 bhp
Optimized fuel con-
sumption
2 12V4000C11R
(T1237K11-128
4)
Industrial / vehicle
main drive
5A continuous opera-
tion, unrestricted
5B continuous opera-
tion, variable
1900 rpm 1193 kW
1600 bhp
Optimized fuel con-
sumption
3 12V4000C11
(T1237K33-132
8)
Industrial / vehicle
main drive
5A continuous opera-
tion, unrestricted
5B continuous opera-
tion, variable
1900 rpm 1286 kW
1725 bhp
EPA Nonroad T1
(40CFR89)
4 12V4000C11R
(T1237K33-132
9)
Industrial / vehicle
main drive
5A continuous opera-
tion, unrestricted
5B continuous opera-
tion, variable
1900 rpm 1193 kW
1600 bhp
EPA Nonroad T1
(40CFR89)
Reference conditions
ID 1 2 3 4
Intake air temperature °C 25 25 25 25
Barometric pressure mbar 1000 1000 1000 1000
Site altitude above sea level m 100 100 100 100
MS150049/04E 2017-04 | Technical Data | 29
TIM-ID: 0000040201 - 002