7 Troubleshooting
7.1 Troubleshooting
Engine does not turn when starter is actuated
Cause Corrective action
Battery low or faulty u Charge or replace (→ manufacturer's documentation)
Battery: Cable connections faulty u Check that cable connections are properly secured
(→ manufacturer's documentation)
Starter: Engine cabling or starter
faulty
u Check if cable connections are properly secured, contact Service.
Engine wiring faulty u Check (→ Page 145)
Engine/generator control system:
Assemblies or connectors
possibly loose
u Perform visual inspection (→ manufacturer's documentation)
DDEC: Plug-in connections
possibly loose
u Check plug-in connections (→ Page 148).
Running gear blocked (engine
cannot be barred manually)
u Contact Service.
Engine turns but does not fire
Cause Corrective action
Poor rotation by starter: Battery
low or faulty
u Charge or replace battery (→ manufacturer's documentation)
Engine wiring faulty u Check (→ Page 145)
Air in fuel system u Vent fuel system (→ Page 102).
DDEC defective u Contact Service.
Engine fires unevenly
Cause Corrective action
Fuel injection: Injector defective u Replace (→ Page 96).
Engine wiring faulty u Check (→ Page 145)
Air in fuel system u Vent fuel system (→ Page 102).
DDEC defective u Contact Service.
Engine does not reach rated speed
Cause Corrective action
Fuel prefilter clogged u Clean or replace filter element.
Easy-change fuel filter clogged u Replace (→ Page 103).
Air filter clogged u Check signal ring position of contamination indicator (→ Page 107).
Injector defective u Replace (→ Page 96).
Engine wiring faulty u Check (→ Page 145)
Engine load too high u Contact Service.
MS150049/04E 2017-04 | Troubleshooting | 53
TIM-ID: 0000002542 - 005

Table of Contents