5.5 Engine – Stopping in manual mode
Preconditions
Engine is not under load.
Engine is running in manual mode.
NOTICE
Stopping the engine when it is running at full load subjects it to extreme thermal and mechanical stress-
es.
Overheating of and, therefore, damage to components is possible!
Before shutting down the engine, allow it to idle until the engine temperatures decrease and constant
levels are indicated.
Preparation
Item Measure
Engine Operate engine at idling speed for approx. 5 minutes.
Stop engine
Item Measure
Switch cabinet, operator
station etc. (depending on
manufacturer)
Press stop button.
Automatic stopping sequence is executed.