8.3.2 Crankcase breather (open-circuit crankcase ventilation) – Filter element
cleaning
Preconditions
Engine is stopped and starting disabled.
WARNING
Compressed air gun ejects a jet of pressurized air.
Risk of injury to eyes and damage to hearing, risk of rupturing internal organs!
Never direct air jet at people.
Always wear safety goggles/face mask and ear defenders.
NOTICE
Cleaning agents should not be left to take effect for too long.
Damage to components is possible!
Observe manufacturer's instructions.
Cleaning filter element
1. Remove filter element (→ Page 81).
2. Clean filter element with cleaning agent.
3. Remove cleaning agent.
4. Blow out filter element thoroughly with compressed air.
5. Install filter element (→ Page 81).
MS150049/04E 2017-04 | Crankcase Breather | 83