8.3.2 Crankcase breather (open-circuit crankcase ventilation) – Filter element
cleaning
Preconditions
☑ Engine is stopped and starting disabled.
WARNING
Compressed air gun ejects a jet of pressurized air.
Risk of injury to eyes and damage to hearing, risk of rupturing internal organs!
• Never direct air jet at people.
• Always wear safety goggles/face mask and ear defenders.
NOTICE
Cleaning agents should not be left to take effect for too long.
Damage to components is possible!
• Observe manufacturer's instructions.
Cleaning filter element
1. Remove filter element (→ Page 81).
2. Clean filter element with cleaning agent.
3. Remove cleaning agent.
4. Blow out filter element thoroughly with compressed air.
5. Install filter element (→ Page 81).
MS150049/04E 2017-04 | Crankcase Breather | 83
TIM-ID: 0000003508 - 005