5.2 Putting the engine into operation after scheduled out-of-
service period
Preconditions
Engine is stopped and starting disabled.
WARNING
In case of out-of-service periods of more than one week: Possible corrosion of components carrying air
or exhaust gas due to weather conditions, e.g. rain or snow.
Risk of injury by flying debris when putting the engine into operation!
Check the components carrying air and exhaust for corrosion.
Do not put the engine in operation if corrosion was detected.
Putting into operation
Item Measure
Engine oil system Check engine oil level (→ Page 108).
Coolant circuit Check engine coolant level (→ Page 116);
Check charge-air coolant level (→ Page 126).
Coolant circuit Heat coolant with coolant preheater (if available; see manufacturer's docu-
mentation).
Engine control system Put into operation (see manufacturer's documentation).
46 | Operation | MS150049/04E 2017-04