134
Ultima S / SL Flex & Pro
3/2019
114060421
Hooklift Multilift Ultima S / SL Flex & Pro
User Manual
>>>
Automatic hook level
Activates automatic hook height setting in loading mode.
Automatic tipping special
The slide position is automatically set according to specication.
Safe speed+ / LoadBoost
The hooklift movement speed is adjusted automatically according to
load.
Automatic sequence
Toggles ON / OFF automatic loading/unloading sequence mode.
Colour Status Description
-- permanently o no operating voltage
orange 1 x on initialisation or reset checks
green 5 Hz
2 Hz
permanently on
no operating system loaded
application is running (RUN)
application stopped (STOP)
red 5 Hz
permanently on
application stopped due to under voltage
system fault (fatal error)
Status LED
Status LED