Check the safety functions of all di󰀨erent movements; tipping, loading and unloading. Do
the checks rst without a container and thereafter with the container.
Safety functions
Check that:
hydraulic body locks cannot be opened during tipping (tipping device approx.
20 in [0,5 m] raised)
moving of hook arm is not possible during tipping
hook arm cannot be moved when the hydraulic body locks are closed
body locks signal light is lit when the locks are not closed.
Check the functioning of the load holding valves with a loaded container:
let the hooklift stay with the container raised for 5 minutes and check that
the tipping device has not descended by itself (g. Tipping device raised)
let the hooklift stay in loading position for 5 minutes and check that the container
has not descended down (g. Loading position).