Ultima S / SL Flex & Pro
3/2019
114060421
Hooklift Multilift Ultima S / SL Flex & Pro
Service Manual
Checking the air lter
Check the condition of the air lter. Clean and replace it as necessary.
Checking the condition of the oil
It is possible to examine ageing and deterioration of the quality of oil in the following way:
dark colour is caused by overheating of oil
milky and/or frothy oil contains water
water can also be seen in separated oil
air bubbles in oil are a sign of too little oil or of a leak in suction line
solid particles indicate a component damage or old oil
air is a sign of oil ageing as a result of overheating.
If you notice any of the above symptoms in oil, change it according to the following
instructions.
Attention!
Hydraulic oils, especially mineral oils, are hazardous to environment. Therefore, follow all
regulations pertaining to collecting and storing oil. Earth material polluted with oil must be
processed according to relevant instructions.
If several successive containers switches are performed, the hydraulic oil may
overheat (>60ºC) making it necessary to install an oil cooler to the system.
Either the ISO VG 22 mineral oil or the HEES ISO VG 32 biodegradable oil is used
at the factory. If biodegradable oil is used, a HEES sticker is attached to the control
valve and the oil tank.