173
Ultima S / SL Flex & Pro
3/2019
114060421
Hooklift Multilift Ultima S / SL Flex & Pro
Service Manual
ERROR CODE
COMMENTS / PROBLEM LOCATION
PROGRAM DESCRIPTION POSSIBLE ACTION CONSEQUENCE
F072
(* Add.Hydraulics3 Out voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F073
(* Add.Hydraulics4 In short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F074
(* Add.Hydraulics4 In voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F075
(* Add.Hydraulics4 Out short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F076
(* Add.Hydraulic4 Out voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F077
SUPPLY VOLTAGE FOR CONTROL UNIT SHORT CIRCUIT 2024 - CONTROL UNIT
SHORT CIRCUIT CHECK POWER WIRES BETWEEN 2024 MODULE AND
CONTROL UNIT
F078
SUPPLY VOLTAGE FOR CONTROL BOX WHEN NOT
CONTROLLED
2024
Voltage when not controlled CHECK THE CABLES
F079
TILT SENSOR VALUES NOT LEGAL OR NOT CONNECTED 2024
Tilt sensor middle frame out
of range
CHECK CONNECTION / REPLACE SENSOR FAST LOWERING
DENIED
F080
TILT SENSOR VALUES NOT LEGAL OR NOT CONNECTED 2024
Tilt sensor subframe out of
range
CHECK CONNECTION / REPLACE SENSOR FAST LOWERING
DENIED
F081
PRESSURE SENSOR VALUES NOT LEGAL OR NOT
CONNECTED
2024
Pressure sensor main cylinder
A out of range
CHECK CONNECTION / REPLACE SENSOR FAST LOWERING
DENIED