Self-moving multipurpose loader MULTIONE
1 Series
Instruction manual (Traslation of original instructions)
CM170001EN - 01.03.17 - 03 (11.07.18)
37/49
MultiOne SRL
9.5 Ordinary maintenance
Frequency Operating point Type of intervention
Every day
Machine Cleaning (see par. 9.7.1)
Joints, levers and lubricators Greasing (see par. 9.7.8)
Hydraulic circuit Oil level check (see par. 9.7.5)
Air filter Cleaning (see par. 9.8.2)
Every week
Tyres Check the pressure (see par. 9.7.2)
Engine
Oil level check (see par. 9.8.1)
Air filter cleaning (see par. 9.8.2)
Joints, levers and lubricators Greasing (see par. 9.7.8)
TAB. 16
9.6 Scheduled maintenance
WARNING
PLEASE CONTACT YOUR LOCAL DEALER AND/OR AN AUTHORISED WORKSHOP FOR SCHEDULED MAINTENANCE.
Frequency Operating point Type of intervention
After the first 50 hours
or first 3 months
Hydraulic circuit
Change the oil filter (see par. 9.7.6)
Check pressure
Adjust pressure
Engine
Change oil
Replace oil filter
Replace fuel filter
Bolts, nuts, screws etc. Check the tightness
Battery Check charge
Every 200 hours
or 6 months
Hydraulic circuit Change the oil filter (see par. 9.7.6)
Engine
Change oil
Clean the air filter
Replace fuel filter
After the first 400 hours
or first year
Engine Check intake and exhaust valves
Every year
Hydraulic circuit
Check pressure
Adjust pressure
Change the oil filter (see par. 9.7.6)
Change oil
Engine
Change engine oil
Change fuel filter
Replace oil engine filter
TAB. 17
MAINTENANCE -9