Self-moving multipurpose loader MULTIONE
1 Series
MultiOne SRL
Instruction manual (Traslation of original instructions)
CM170001EN - 01.03.17 - 03 (11.07.18)
46/49
9.9 Troubleshooting
Problem Possible cause Solutions
Engine does not crank
Discharged battery, low battery voltage Check and charge the battery.
Blown fuse Check fuses. If the fuse blows again, find out
the cause. Contact service.
Battery cables poorly connected or
disconnected.
Check battery cables and posts, clean and
retighten if necessary.
Engine cranks but does not start, or
starts and stops immediately
No fuel or wrong type of fuel Drain the tank and fill the tank with correct
type of fuel. Drain water from the fuel filter.
Prime the fuel system.
Engine does not get fuel, clogged fuel
filter or fuel line.
Make sure that the fuel hoses and fuel filter
are clean and have not been frozen. Replace
fuel filter, clean fuel lines.
Battery discharged or damaged Charge the battery or replace if damaged.
Engine overheats
Overload Use attachment at lower engine rpm, check
attachment for faults.
The loader does not move even after the
parking brake has been released
Low hydraulic charge pressure. Contact service for pressure check.
TAB. 18
10 SPARE PARTS
WARNING
THE ORIGINAL PARTS FOR ANY CHANGES MUST BE REQUIRED ONLY TO THE DEALER OR AUTHORISED SERVICE CENTRE,
COMMUNICATING MACHINE MODEL, SERIAL NUMBER AND YEAR OF MANUFACTURE.
10.1 Filter code
Model
Type of filter M1 1.1
Oil engine filter C039007
Air cartridge filter C039150
Hydraulic oil filter C036601
TAB. 19
10- SPARE PARTS