Manual 
  43 
- Every time you press the REV/CLR button you 
  switch the flight phase between: 
    THERMIK1 locked, and 
    THERMAL1 unlocked. 
- Once you have set the desired state, 
press ENTER to conclude the procedure 
(or press the 3-D digi-adjuster). 
!
 The current flight phase, which is marked with an 
 X, cannot be locked: 
1 SPEED1    X --- 
12.10.5.  Copying flight phases 
Once you have established the correct settings in one 
flight  phase,  you  can  copy  the  values  into  another 
flight  phase  and  then  modify  them.  This  avoids  the 
need to re-enter all the settings from the start. 
!
 Only the current flight phase can be copied. 
 The destination (target) flight phase for the copy 
 process must be an unlocked flight phase. 
This is the procedure for copying the current flight 
phase: 
  - Open the main menu Memory (button I) 
- Select the menu Flight phase 
- Press ENTER twice to select the X 
 (or press the 3-D digi-adjuster twice): 
¦Flight phase 
  ¨Exit 
 1 SPEED1    X  I> 
  - Now select the destination (unlocked flight phase) 
  using the 3-D digi-adjuster: 
¦Flight phases 
  ¨Exit 
 1 SPEED1    X  I> 
 2 NORMAL      --- 
 3 THERMAL1  c --- 
 4 START1   --- 
 
 Time        OFF 
  - Confirm with ENTER 
 (or press the 3-D digi-adjuster). 
The  marker  jumps  back  to  the  code  number  for  the 
current  flight  phase.  Only  the  name  for  the  “Target” 
phase is retained. All flight phase specific transmitter 
control  settings  are  now  the  same  as  in  the  current 
flight phases. 
12.10.6.  Changing flight phase names 
You can select any of the thirteen pre-set names for 
the flight phases: 
The only purpose of the name is to provide additional 
information; it has no influence on the characteristics 
of the corresponding flight phase. The crucial aspect 
for the properties is always the flight phase number. 
Once you have activated an input field for the name, 
you can select a suitable name from those on offer: 
¦Flight phase 
 ¨Exit 
 1 SPEED1    X --- 
 2 NORMAL      --- 
 3 THERMAL1 --- 
 4 START1   --- 
 
 Time         OFF 
 
1 
NORMAL 
 
6 
SPEED1 
 
11 
SCHWEBEN 
 
2 
START1 
 
7 
SPEED2 
 
12 
3D 
 
3 
START2 
 
8 
RUNDFLUG 
 
13 
ACRO 
 
4 
THERMIK1 
 
9 
LANDUNG 
 
 
 
 
5 
THERMIK2 
 
10 
AUTOROT 
 
 
 
 
Der  Name  dient  nur  als  zusätzliche  Information  und 
hat  keinen  Einfluss  auf  die  Eigenschaften  der 
jewiligen  Flugphase.  Entscheidend  für  die 
Eigenschaften ist immer die Nummer der Flugphase. 
Wenn  Sie  das  Eingabefeld  für  den  Namen  aktiviert 
haben, können Sie einen geeigneten Namen auswäh-
len. 
¦Flugphasen 
 ¨Exit 
12.10.7.  Setting a transition time 
The switch from one flight phase to another can occur 
immediately, or  alternatively  you can set  a  transition 
period of 1,  2  or 4 seconds (smooth  transition). The 
latter reduces the loads on the model and the power 
system. 
This is the procedure for setting a transition Time 
between flight phases: 
  - Open the main menu Memory (button I) 
- Select the menu Flight phase 
- Press ENTER (or press the 3-D digi-adjuster) 
  to open the menu 
- Select the Time line (see fig. 12.10.7.1.) 
- Press ENTER (or press the 3-D digi-adjuster) 
  to open the set-up window 
- Use the 3-D digi-adjuster to set a transition period 
  (see fig. 12.10.7.2.): 
  1sec, 2sec, 4sec or OFF 
- Press ENTER (or press the 3-D digi-adjuster) 
 to confirm the selected setting. 
¦Flight phase 
 ¨Exit 
 1 NORMAL   X --- 
 2 ACRO    --- 
 3 START1   --- 
 4 LANDING  --- 
 
  Time     OFF 
     Fig. 12.10.7.1.: Time line selected 
¦Flight phase 
 ¨Exit 
 1 NORMAL   X --- 
 2 ACRO     --- 
 3 START1   --- 
 4 LANDING  --- 
 
  Time     2sec 
  Fig. 12.10.7.2.: Time set to 2 sec