5-43 5-43
RX MOTOR
1. Remove the Cover option. (See page 5-20)
2. Remove the Cover shield. (See page 5-20)
3. Remove the Cover back. (See page 5-32)
4. Remove four RX motor mounting screws and disconnect the connector, and then remove the RX
MOTOR.
RX motor
MOTOR DUPLEX
1. Remove the Cover option. (See page 5-20)
2. Remove the Cover shield. (See page 5-20)
3. Remove the Cover back. (See page 5-32)
4. Remove two Motor duplex mounting screws and disconnect the connector, and then remove the
MOTOR DUPLEX.
Motor duplex