3-4 Cleaning the Scanning Area
Cleaning the Scanning Area
Cleaning the Automatic Document Feeder (ADF)
If the document feeder rollers or scanning glass are dirty, the documents may become
dirty and black lines may appear in the scanned images. This can also cause a document
jam.
Clean the ADF at least once a month to ensure that documents are transmitted with high
image quality.
IMPORTANT
Do not use benzene or thinner as cleaning agents, as they may damage the plastic and
paint of the machine.
MFX-2570 Users
Open the ADF cover.
1
Use a cloth moistened with
2
water to clean the face of the rollers and pads.
Rotate the rollers by hand to clean the entire roller surface.