10 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
DN 1577
7
6
54
321
ACUSENSOR M
ACUSENSOR M
FOLD SIDE ACTIVATION
APROACH SIDE ACTIVATION
FOLD SIDE SAFETY
RED
BLACK
BROWN
GREEN
V-00741
V-00741
ACUSENSOR M
V-00741
ACUSENSOR M HARNESS
A-01292
1
2
3
1
2
4
1
2
6
To Terminal # on Opus Control
ACUSENSOR M HARNESS
A-01292
ACUSENSOR M HARNESS
A-01292
YELLOW
GREY
7
RED
BLACK
BROWN
GREEN
YELLOW
GREY
7
RED
BLACK
BROWN
GREEN
YELLOW
GREY
7
ACUSENSOR M TO OPUS IN FOLDING DOOR
WITH MONITORING
DN 1579
1
2
3
4
BROWN, GREY
RED, GREEN, BLUE
BLACK, WHITE
YELLOW
ACUSENSOR M
SWING SIDE (SAFETY)
V-00741
ACUSENSOR M HARNESS (WITH CONNECTOR)
P.N. A-01292
RED
BLACK (or Black with Red Stripe)
BROWN
YELLOW
ACUSENSOR M TO U-SERIES IN SLIDE DOOR WITH MONITORING
FROM U-SERIES CONTROL
BLACK
WHITE
BROWN
YELLOW
RED
GREY
GREEN
BLUE