19 of 28
www.NabcoEntrances.com AcusensorMInstallaonManual
Rev 8-25-17 P/N C-00187
Sensitivity
17 18 Mounting Height
SH
(Super High)
X 98” thru 118” (2.5m thru 3.0m)
X Use if sensivity is too LOW with Switch Seng (H)
IP Mode is ulized when Sensors are placed within the same Area and/or when Sensors are facing each other. This is true for mulple
Acusensor M Sensors and/or older versions of the Acusensor, Acuvision, and/or Acumoon sensors.
To prevent Sensor Malfuncon, the IP Mode Seng must be dierent from that on each other sensor.
Table 18 IP Mode
IP Mode
19 20 Description
A Default for the Acusensor M
B Suggested IP Mode for 2nd Sensor
C Suggested IP Mode for 3rd Sensor
D Suggested IP Mode for 4th Sensor
The Area Adjuster is a Phillips Head screw that the installer turns to angle the Sensor:
X Counter Clockwise to adjust the Detection Area Pattern farther out.
X Clockwise to adjust the Detection Area Pattern farther in.
An Angled Spacer (sold separately) can be used to provide a Presence Detecon Area outside of normal Depth.
1. Turn OFF power.
2. Go to Area Adjuster located on the Right hand side of Acusensor M.
DN 1565
Depth Learn Time Anti-Noise Anti-Environment Sensitivity IP Mode
91011910 11 12 13 14 15 16 17 18 19 20
6 2 30s Normal Normal H A
5 5-6eco 15s Special
Anti-Vibration
M B
4 4-6eco 60s Anti-Snow I L C
3 Area Check 300s Anti-Snow II SH D
Area Adjuster
0
-10
Degree Indicator Charts
Degree Indicator
Area Adjuster
Figure 10 Area Adjuster