14 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
1. Turn OFF power.
2. Li the reusable protecon ap located on the Le hand side of Acusensor M.
a. Underneath the ap are three groups of Switches.
DN 1562
Depth Learn Time Anti-Noise Anti-Environment Sensitivity IP Mode
91011910 11 12 13 14 15 16 17 18 19 20
6 2 30s Normal Normal H A
5 5-6eco 15s Special
Anti-Vibration
M B
4 4-6eco 60s Anti-Snow I L C
3 Area Check 300s Anti-Snow II SH D
Switches 1-8
Switches 9-16
Switches 17-20
Figure 7 Switch Settings
3. Go to the middle of the Acusensor M to locate a diagram for how to set switches 9 thru 20.
DN 1563
Depth Learn Time Anti-Noise Anti-Environment Sensitivity IP Mode
91011910 11 12 13 14 15 16 17 18 19 20
#6 2 #30s #Normal #Normal #H #A
5 5-6eco 15s Special
Anti-Vibration
M B
4 4-6eco 60s Anti-Snow I L C
3 Area
Check
300s Anti-Snow II SH D
#Default Se ng IP Mode Interference Protec on
Depth Adjusts depth of Presence Detection Area (grid)
Learn Time The amount of time it takes for the sensor to learn the area, or relearn if a normally stationary
object is moved. ANSI requires minimum 30sec.
Anti-Noise Helps prevent false detection caused by electrical noise or nearby light sources.
Anti-Environment Helps prevent false detection caused by vibration, insects, snow.
Sensitivity Adjust signal strength for detecting moving pedestrians or objects. Example: For slow moving
pedestrians or objects, sensitivity option should be on Medium or High.
IP Mode Helps prevent interference caused by sensors near each other.
Figure 8 Switch Setting Diagram