Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17


The purpose of this manual is to familiarize the installer and purchaser with the proper installaon and operaon of the Acusensor
M. It is essenal that this equipment be properly installed and operaonal before the door is used by the public. It is the installer’s
responsibility to inspect the operaon of the entrance system to be sure it complies with any applicable standards. In the United
States, ANSI Standard 156.10 (Full Energy) covers these types of doors. Other local standards or codes may apply. Use them in
addion to the ANSI standard.
Instruct the building owners and operator on the essenals of the operaon of the door and this device. The owner should follow
these instrucons to determine whether the door is operang properly and should immediately call for service if there is any
malfuncon. All installaon changes and adjustments must be made by qualied, NABCO trained technicians.
If aer troubleshoong a problem, a sasfactory soluon cannot be achieved, please call Nabco Entrances at 1-877-622-2694
between 8 am – 4:30 pm Central me for addional assistance.

Acusensor M is mounted on the Header Cover for all Slide Door Units, Swing Door Units, and Fold Door Units. The Acusensor M is
used to detect changes of mulple near-infrared rays that beam from the Sensor down to various points on the oor. The Acusensor
M can detect a moving pedestrian or object, or a staonary pedestrian or object. Upon Presence Detecon, the Acusensor M
outputs a detecon signal to Control. The Control automacally sends a signal to the Motor/Operator, the Motor/Operator opens
the automac door.
The Acusensor M was developed based on the concept of safety, comfort, reliability and mulpurpose.

All wiring must conform to standard wiring practices and be in accordance with national and
local electrical codes.
Note:  It is recommended for the Installer to use an Electrical Conduit to house all incoming 120 VAC wires.
Table 1 
Specification Description
Sensing System Acve reecve near infrared system (Moon/Presence)
Life Expectancy (5) years. LED illuminates a:
White light during Learning that blinks twice every (5) seconds
Green light during Normal Operation that blinks twice every (5) seconds
• Flashing LEDs do not indicate that the Sensor is failing.
• Flashing LEDs indicate that the Sensor has been in use for a period of me, and replacement
is recommended. This is done to ensure connued safe operaon of the door.
Applicable door Sliding door/Swing door/Folding door
Detecon Area
Without angled spacer
• Width 114”(2.9m) x Depth 71”(1.8m) (at mounng height 87”(2.2m))
With angled spacer (sold separately)
• Width 114”(2.9m) x Depth 78”(2.0m) (at mounng height 87”(2.2m))
The width and depth of a Detecon Area may vary. For details, please refer to Table 3-1. This is
typically the result of:
A variance in mounting height.
Normal manufacturing and component tolerances.

Use of spacers for mounting.
Output Contacts Rang Non-polarized, No voltage, Semi-conductor relay output 30 VAC/50VDC, 0.1A (Resistance Load)
N.C. or N.C.
When Set to N.O.
No Detection “Open
Detection “Closed”
Power Failure “Open”
Sensor Malfunction “Closed”
WARNINGWARNING
Question and Answer IconNeed help?

Do you have a question about the Nabco Acusensor M and is the answer not in the manual?

Nabco Acusensor M Specifications

General IconGeneral
TechnologyMicrowave
Detection ModeMotion
MaterialPlastic
Mounting Height2.5m - 4m
Power Supply12-24V DC
FunctionActivation

Summary

Safety and Warnings

Warning Label Definitions

Explains the meaning and hierarchy of different warning labels used in the manual.

Key Safety Recommendations

Provides essential safety practices for installation and operation to prevent injury or damage.

Presence Detection Area Configuration

Acusensor M Installation Procedures

Mounting Sensor to Header

Step-by-step instructions for physically securing the Acusensor M sensor unit onto the door header.

Switch Settings Configuration (1-8)

Operation Mode Settings (Switches 1-2)

Configuration of switches 1-2 to define the door's operational monitoring mode.

Output Logic (Switch 3)

Setting switch 3 to determine the sensor's output logic (Normally Open or Closed).

Input Logic (Switch 4)

Setting switch 4 to configure the sensor's input logic behavior.

Advanced Switch Settings (9-20)