Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
Table 10 Depth for Operation Mode: Doorway 2
Depth
9 10 11 Detection Area Diagram 9 10 11 Detection Area Diagram
6 2
5 N/A ECO Mode does not work well with
Swing and Fold doors.
4 N/A ECO Mode does not work well with
Swing and Fold doors.
3 Area
Check
Operaon Mode X Doorway monitoring works
X Depth Rows are Acve
X Depth Rows will never be Acve
X If Row 1 is Acve, mis-detecon will occur on
Swing Doors and Fold Doors
Inacve Depth Rows are not Acve.

If mounting height for Sensor is low, movement can easily be detected within multiple rows at
the same time. Because of this, the ECO Mode may not operate correctly.
Note:  ECO Mode is an acronym for Ecological Friendly Mode, also known a Direconal Sensing.
Note:  ECO Mode is not used for Doorway 2 operaon.
ECO Mode is a funcon that decides whether movement is coming toward the door, or away from door (direconal sensing). If the
Sensor decides movement is going away from door, the High or Low feature will determine how far the object gets before the door is
allowed to close.
Mode Depth Rows Description
Low 5 and 6 Output stops when and object is detected moving away through rows 5 to 6.
1 thru 4 Output maintains when and object is detected in rows 4 to 1.
High 4, 5, and 6 Output stops when and object is detected moving away through rows 4 to 6.
1 thru 3 Output maintains when and object is detected in rows 3 to 1.



Area Check Mode is used for adjusng the depth of a detecon area, and conrm test command input.
An unique LED color is assigned to each Depth Row (1 thru 6). When the installer selects a Depth Row, the Sensor will illuminate each
assigned LED color.
If mulple Depth Rows are detected at the same me the Sensors LED will illuminate the color assigned to the Depth Row closest to
the face of Door.
CAUTION