Rev. 3-12-13 Part #15-9000-30
www.NabcoEntrances.com U30 Microprocessor Control
5-25 Adjustment Procedures
Extra Funcon Adjustments
Adjustment Descripon
connued...
Auxiliary Output 2
Two Sequenal Door
Operaon
Instructs the Transistor to turn ON thereby
sequenally acvang a second Slide door for a set
me period. This requires adjusng “Output Timer 2”
to select the me delay between the rst and second
door operaons.
Three Signal at Full Closed Transistor will turn ON to indicate the Slide door
reached a fully closed posion.
Four Break Away The transistor will turn ON if the door is broken out.
Five Break Away or Door
Open Condion
Transistor will turn ON if:
● Slide door is broken out
● Slide door is not fully closed
Six Error Detecon Transistor will turn ON if the U30 Microprocessor
Control detects any error except Error 5.
Seven No Output