18
IOM
IOM
W415-2288 / 08.29.2019
H68.3.5
8. When installed, the Wall Sleeve must protrude
1/2” MIN. to 1” MAX. beyond the exterior  nished wall
to allow proper water evacuation through the drain holes
in the bottom panel. See FIG. 8.
INSTALLATION CREW MUST ADHERE TO ALL LOCAL/NATIONAL SAFE WORK PRACTICES
INCLUDING EMPLOYING APPROPRIATE FALL ARREST EQUIPMENT
WARNING
! !
Flashing
Finished Wall
Wall Sleeve
Flashing
PROTRUDE
1/2” MIN.-1” MAX.
PROTRUDE
1/2” MIN.-1” MAX.
OUTSIDE
INSIDE
8
9. Wall sleeve can be installed from inside or outside the
building (FIG. 9). The side and top brackets’ position need
to be adjusted to suit the method and building material.
9
Install the wall
sleeve into the
wall until the
support brackets
are set on wall
edge.
4.4.2 Wall Sleeve Installation