46 Installing the Water Heater
WARNING
Periodically inspect all vent pipe connections.
The VID is not intended and should not be
relied upon to detect all instances of vent pipe
movement or separation from the collar.
Vent
Installation
Detector (VID)
Detectable*
* If inserted 2-
3
/
4
" (70 mm), then VID should detect
vent pipe.
Undetectable**
** VID can not detect if the vent pipe is leaking or
disconnected at any point between the water
heater and the exterior vent location or if the vent
is blocked for any reason.
WARNING
Carbon Monoxide Hazard
To prevent serious injury or death:
ALWAYS visually inspect the vent pipe before
inserting the vent pipe into the water heater
collar. The vent pipe inserted into the water
heater exhaust collar must be free from
damage or defects for the vent installation
detector to operate properly. If the vent pipe
is damaged, then replace it with new vent
pipe.
The vent installation detector only detects
separation of the vent pipe from the water
heater exhaust collar if fully inserted 2-
3
/
4
"
(70 mm). The vent installation detector will
not detect the separation of connected vent
pipe if the joints become detached or are
leaking flue gas that may contain carbon
monoxide.
It is the installer's responsibility to install the
vent pipe properly, to check for leaks, and to
adequately secure the water heater to the
wall.
2-
3
/
4
" (70 mm)

Table of Contents

Other manuals for Navien NPE-210A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-210A2 and is the answer not in the manual?

Navien NPE-210A2 Specifications

General IconGeneral
BrandNavien
ModelNPE-210A2
CategoryWater Heater
LanguageEnglish

Related product manuals