EasyManua.ls Logo

NCE Power Cab - Page 21

NCE Power Cab
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
the “down” direction is continued. Pushing the knob up will reduce the reverse
speed to zero then increase it in a forward direction. The factory setting is 2 for
“normal” Operation
6)Press ENTER to accept the existing Ballistic Tracking Rate or enter a new rate.
Entering a low number will cause the speed knob to change locomotive speed
more slowly as the knob is turned. Larger numbers will cause a greater change of
speed as the knob is turned. The factory setting is 3 and values from 0-7 will
be accepted.
7)Press ENTER to accept the Speed Button Repeat Rate. This is the rate at which
the 4 speed control buttons repeat. Smaller values will make the buttons repeat
faster. The acceptable range is 16 to 255. The factory setting is 32.
8)Press ENTER to accept the current OPTION key value. If you wish to change it
enter a number from the Key Table Chart following this section. The factory value
is 94 so the OPTION button will act as BRAKE button.
9) Press ENTER to accept the “shifted” value for key number 1. If you wish to
change it enter a number from the Key Table Chart following this section. See the
Table of Factory Default Values for Shifted Keys on page 21 for the preset factory
values.
10) Use the same procedure described in step 9 to accept or program keys number
2 through 32. Remember you can press PROG/ESC to exit at any time. If you
stick it out to key 32, press ENTER to return to normal operations mode.
Key Table Chart
Value Key Name Value Key Name
64 Enter 96 Assign Loco to Cab
65 Program 97 Program on Main
66 Recall 98 Set Clock
67 Direction 99 Use program track
68 Setup consist 100 Setup command station
69 Add loco to consist 101 Setup Procab
70 Delete loco from consist 102 Setup macros
71 Kill consist 103 Setup old consist
72 Select loco 104 Setup advanced consist
73 Horn/Whistle 105 Display LCD lines 3 and 4
74 1 Speed step faster 106 Forward
75 1 Speed step slower 107 Reverse
76 Emergency Stop 108 Reserved
77 Bell 109 Reserved
78 Select Accessory 110 Reserved
79 Expn (Expansion) key 111 Momentum
80 Headlight, Zero key 112 F10
81 F1, number 1 key 113 F11
82 F2, number 2 key 114 F12
83 F3, number 3 key 115 Reserved
84 F4, number 4 key 116 Reserved
85 F5, number 5 key 117 Reserved
86 F6, number 6 key 118 Reserved
87 F7, number 7 key 119 Reserved
88 F8, number 8 key 120 Reserved
89 F9, number 9 key 121 Reserved
90 4/10 speed steps faster 122 Extended Function Control
91 4/10 speed steps slower 123 Aux Analog Button Down
92 Macro 124 Aux Analog Button Up
93 14/28/128 select 125 “no key” pressed
94 Brake (factory setting) 126 Reserved
95 Do not use 127 do not use