4-94 BIOS Setup
. IRQ [IRQ11]
. Device Mode [Standard Serial Po. . .]
. ►Serial Port 4/D Configuration
. Serial Port [Enabled]
. Device Settings IO=2E8h; IRQ=10;
. I/O Base Address [0x2E8]
. IRQ [IRQ10]
. Device Mode [Standard Serial Po. . .]
. ►Parallel Port Configuration
. Parallel Port [Disabled]
► H/W Monitor
Smart Fan Mode [Automatic Mode]
Fan OFF temperature limit 10
Fan Start temperature limit 40
Fan Start PWM 50
PWM Slope [2 PWM]
Hardware Health Monitoring Typical (Acceptable Range)
CPU Die Temperature +46°C (less than 55°C)
CPU VRM Temperature +51°C (less than 55°C)
System Temperature +51°C (less than 55°C)
CPU Fan Speed [5192] (min 2500)
System Fan Speed [N/A]
VDIMM +1.488 V (1.4 - 1.6 V)
VCORE +1.088 V (0.25 - 1.52 V)
VCC3 +3.344 V (3.04 - 3.57 V)
+12V +12.096 V (11.2 - 12.8 V)
VCC5 +5.004 V (4.6 - 5.4 V)
VAXG +0.416 V (0.25 - 1.52 V)
VBAT +2.912 V (< 2.9 V)