3-14 Configuring Your System
Thermal Sensor Submenu
Feature
Choices or
Display Only Description Your Setting
Thermal Sensor Disabled
Enabled
When enabled determines if
the BIOS will disable boot (if
temperature is not within a
safe range).
Upper Limit
50 (11 to 80)
Sets the upper temperature
limit in Centigrade.
Lower Limit
5 (0 to 69)
Sets the lower temperature
limit in Centigrade.
Wake On Events Submenu
Feature
Choices or
Display Only Description Your Setting
Wake On LAN Disabled
Enabled
Enables Wake ON LAN
support.
Console Redirection Submenu
Feature
Choices or
Display Only Description Your Setting
Serial Port Address
Disabled
Serial Port 2
(3F8h/IRQ4)
Serial Port 2
(2F8h/IRQ3)
If enabled, the console will be
redirected to this port.
If console redirection is
enabled, this address must
match the settings of serial
port 2.
Baud Rate 57.6K
19.2K
Enables the specified baud
rate.
Flow Control No Flow Control
XON/OFF
Enables flow control.
Console
Connection
Direct
Via Modem
Indicate whether the console is
connected directly to the
system or a modem is used to
connect.