CHAPTER 7 SPECIFICATIONS
UNIVERGE NEAX 2000 IPS General Description Page 168
Issue 5
System Capacity
IPS System Capacity (Single MP System)
System Capacity Note 1
Item
1PIM 2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM
64 128 192 256 320 384 448 512
(No. of Ports)
LT Card
(No. of Cards)
12 24 36 48 60 72 84 96
Max. 256 ports per system
(No. of Ports)
AP Card
(No. of Cards)
12 24
Total Number of Lines (Analog Single Line Tel. + Dterm) 64 128 192 256 320 384 448 512
IP PAD (No. of Channel)
Note 2
64 128 192 256
Standard 64 128 192 256 320 384 448 512 Analog Single Line Telephone
(Lines)
Long Note 3 48 96 144 192 240 288 336 384
Standard 64 128 192 256 320 384 448 512
Dterm (Lines)
Long 24 48 72 96 120 144 168 192
DtermIP/ INASET/ SP30 (Peer to Peer Connection) 952 888 824 760 696 632 568 504
Dterm PS 512
Zone Transceiver (ZT)
16 32 48 64 80 96 112 128
P-P Connection
24 32 32 32 32 32 32 32
ISDN Terminal (2ILCC)
P-MP Connection
48 64 64 64 64 64 64 64
Loop Start
64 128 192 256 256 256 256 256
Central Office Trunk (Lines)
DID w/4DIT 48 96 144 192 240 256 256 256
2W or 4W E&M 48 96 144 192 240 256 256 256
Tie Line Trunk (Lines)
Type 1 w/PW122 12 24 36 48 60 72 84 96
CCIS Trunk (Peer to Peer Connection) Max. 127
1.5M DTI: 10, CCIS: 8
DTI/CCIS Digital Link
Note 4
2M 8
1.5M (PRT) 8
ISDN
4BRT (card) 6 12 18 24 24 24 24 24
IP Trunk 1 2 3 4 5 6 7 8
PFT Connections 8PFT 8 16 24 32 40 48 56 64
3-Party Conference Max. 16 conference groups per system
8-Party Conference Group Max. 8 conference group per system
32-Party Conference Group Max. 8 conference group per system
DTMF Sender Max. 32 circuits per system
DTMF Receiver 16 DTMF Receiver
SN716 Desk Console 8
Attendant Terminal (Dterm ATT Position) Max. 8 sets per system
Note 1:
"PIM" in this table means "Physical PIM."
Note 2: Number of IP PAD card is maximum 2 per FP.
Note 3: Message Waiting Lamp is not available when the 4LLC is mounted in slot 08 to 11.
Note 4: The total number of trunk line and DTI channel shall be 256 or less. (Each trunk line and DTI
channel are required to assign the “Trunk Number” by system data programming and maximum
number of system parameter for “Trunk Number” is 256.)