CHAPTER 4 EQUIPMENT DESCRIPTION
UNIVERGE NEAX 2000 IPS General Description Page 90
Issue 5
Chapter 4 Equipment Description
Modules
Abbrev Name Code Remarks
SN1729
PIMMJ
PIM
Port Interface Module (PIM)
Maximum 64 physical ports per PIM.
Houses two batteries for protection from short power
interruption (for 30 minutes).
At maximum configuration, the system consists of
eight PIMs, and provides a total of 512 physical ports
(64 ports × 8).
SN1730
PIMMK
PIM
Port Interface Module (PIM) for Backup CPU System -
Maximum 64 physical ports per PIM. Houses two
batteries for protection from short power interruption
(for 30 minutes).
One PIM is required per Backup CPU System.
COVER
PARTS
ASSEM
COVER
PARTS
ASSEM
Cover Parts Assembly
One cover parts assembly is required for each PIM.
SN1545
BASERE
TOP COVER
ASSEM
BASE/TOP
ASSEM
Base/Top Cover Assembly
One base and top cover assembly is required for each
stack.
SN1731
BATTMH
BATTMH
Battery Module for housing PIM or CS (ZT) backup
batteries
Houses two pairs of batteries for protection from long
power interruption (for 3 hours).
SN-1737
IPSMJ
MC
Modular Chassis (MC) with Ringer. Each MC
supports 56 physical ports (7 LT/AP card slots).