CHAPTER 2 SYSTEM CONFIGURATION
UNIVERGE NEAX 2000 IPS General Description Page 45
Issue 5
This feature is available in the Retrofit System (used as Main Site). The system that
using the following MP cards can be mixed used in Remote PIM over IP system in
any combination.
Main Site: PN-CP24-D, PN-CP27-B, PN-CP31E, PN-CP26-B, PN-CP28-B
Remote Site: PN-CP31-D, PN-CP24-D, PN-CP26-B
NOTE: PN-CP27-B/PN-CP28-B cannot be used as Backup CPU system in Remote Site.
This feature is not compatible with Fusion service of 2400 IPX.
Conditions for System Configuration
The number of Remote Sites is a maximum of 30.
The total number of FP/AP at Main Site and all Remote Sites should not exceed 64
including the MP built-in FP, Virtual FP, and Virtual IPT.
The number of FP/AP accommodated at one Remote Site should be a maximum of
eight including the MP built-in FP.
Remote Site can accommodate the following FP/AP/LT cards.
-
FP: One MP built-in FP and two Virtual FP
-
AP: BRT, 24DTI, 24PRT (ISDN-PRI)
-
LT: 8IPLA, DLC, LC, COT, ODT
NOTE:
Attendant Console, Desk Console, Add-On Module, are not mountable at Remote
Site.
Remote Site cannot accommodate the following FP/AP/LT cards.
-
FP: FP card (CP15) is not mountable at Remote Site.
-
AP: AP00 (SMDR), AP00 (DBM), ICH, CCH, DCH (Q-SIG/Q931a), 4RSTB
(MFC/T1-ANI/E911), CFTC (32-party conference), IPT
- LT: 8RSTG (PBR), ILC (ISDN Terminal), 4RSTF (Caller ID station), PN-
8LCAD (LLC), PN-4LLCB (LLC), PN-8PFTB (PFT), 4VCT, DK00, DAT
NOTE: Four-line built-in PBR on the MP card is available at Remote Site.
MP built-in FP must be set to each Remote Site.
The port for FP card/MP built-in FP must be assigned with every 8 port. If the
assignment value cannot be divided by 8, the value that the remainder is omitted is
assigned to the FP card/MP built-in FP automatically.
The available IP-PAD card in the Remote Site is PN-8IPLA.
For the system capacity of ISDN system or CCIS system, refer to the system capacity
of each system manual. Set the whole Remote PIM over IP system within the system
capacity and be sure to mount the handler card in the Site where the interface card is
installed.
The number of ports accommodated at one Remote Site should be a maximum of
256. This is the sum of maximum 128 physical ports (one built-in FP), maximum
128 IP ports (two Virtual FP), and AP ports such as ISDN, etc.