Chapter 2 TROUBLESHOOTING
2-32 NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Line Status and Remedial Action for Hardware Test
•IP STATION
Line Status and Remedial Action for Software Test
• SINGLE LINE TELEPHONE/MULTILINE TERMINAL
INDICATED
DATA
LINE STATUS REMEDIAL ACTION
06 DLC blade down Replace the blade with a known good one and check to
see if the same failure occurs.
08 Line failure detect Replace the terminal with a known good one and check
to see if the same failure occurs.
INDICATED
DATA
LINE STATUS REMEDIAL ACTION
00 Terminal is not connected Check the LAN cable connection between the ter-
minal and the PBX.
Check the condition of LAN cable connection by
transmitting the ping packet.
Confirm the condition of the LAN device (such as
power of the HUB) connected to the VoIPDB.
01 Terminal is connected No action is required.
INDICATED
DATA
LINE STATUS REMEDIAL ACTION
01 Idle No action is required.
02 Line Lockout Place the handset of the station in line lockout back
onto the hookswitch.
Other than
01, 02
Busy No action is required.
1
2
3