Chapter 1 MAINTENANCE SERVICES
1-47 NWA-033627-001 Rev.4.0
95ch1001.fm
QoS DISPLAY ON IP MULTILINE TERMINAL
Service Conditions
(1) Number of lost packets, CODEC type, and Payload size are displayed with pressing the Function key
that has been set during a communication.
(2) The displayed QoS information on the LCD is updated every 5 seconds.
(3) All information sent from the PBX is not displayed while the QoS information is displayed on the
LCD.
(4) To stop the display of QoS information, press Soft key of Exit. If you do not that, the QoS
information will keep being displayed.
(5) This feature is available for the IP Multiline Terminal version 2.81 or later.
(6) When using this feature for SIP Multiline Terminal, the data assignment of the QoS Display key
(second data of CM90 Y=00 is set to “F1058”) is not necessary. QoS information is displayed with
pressing the HELP key continuously.
Programming Procedure
DESCRIPTION DATA
Assign the QoS Display key to the IP Multiline
Terminal.
NOTE: This data is not activated even if this
data is assigned to the DT700 Series
Feature Keys.
(1)
(2)
Y=00
My Line No. + + Key No.
F1058: QoS Display on
IP Multiline
Terminal
START
CM90
,
END
NOVEMBER/21/2008